<ErrorNumber>22020</ErrorNumber>
<ErrorFamily>Autoloader 2</ErrorFamily>
<ErrorMessage>
ALE2: Plate load failed, remove from drum and select "Plate Removed"
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>ThermoFlex</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
If the problem persists, ensure that 'drum chkfly' is set to zero.
The ThermoFlex doesn't actually have a flyoff sensor so if this is
occuring, this is the quickest way to diffuse it.
On the ThermoFlex, the drum vacuum was monitored and used as a flyoff
indicator, check the value for al dvt, it should be 0 as should drum chkfly.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Follow instructions, remove plate and select 'plate removed'.
</text></DescriptionText>
</OperatorAction>
<Cause>
The drum has been put into a state where it thinks a flyoff has occured.
This has been followed with a drum init or unload command.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/drum_cfg_chkfly.xml</LinkAddress><LinkTitle>NVS: drum chkfly</LinkTitle></Link>
<Link><LinkAddress>../nvs/al_cfg_dvt.xml</LinkAddress><LinkTitle>NVS: al dvt</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:51 2008 PST
</Updated>
<Links>
</Links>
</Error>